一本加勒比HEZYO无码专区,国产精品99久久久久久宅男 ,亚洲AV永久无码国产精品久久,少妇久久久久久被弄到高潮

服務(wù)熱線:
15821734033
產(chǎn)品展示

您現(xiàn)在的位置:首頁  >  產(chǎn)品展示  >  ELISA試劑盒  >  人ELISA試劑盒  >  人血管內(nèi)皮生長因子(VEGF)Elisa試劑盒說明書

人血管內(nèi)皮生長因子(VEGF)Elisa試劑盒說明書

  • 產(chǎn)品型號:
  • 產(chǎn)品時間:2024-08-10
  • 簡要描述:人血管內(nèi)皮生長因子(VEGF)Elisa試劑盒說明書
    上?;鄯f生物科技專業(yè)生產(chǎn)研發(fā)經(jīng)營穩(wěn)定、優(yōu)質(zhì)、高效、實用的ELISA試劑盒,公司提供ELISA試劑盒免費代測,ELISA試劑盒批發(fā)價零售,ELISA試劑盒專業(yè)生產(chǎn)廠家,ELISA試劑盒進口品牌!
  • 產(chǎn)品簡介

人血管內(nèi)皮生長因子(VEGF)Elisa試劑盒說明書

Human Vascular Endothelial cell Growth Factor (VEGF) ELISA Kit

(48Tests)

Store all reagents at 2-8°C Collect sample: serum or blood plasma Assay range 5.0 pg/ml -950 pg/ml


FOR LABORATORY RESEARCH USE ONLY.


NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!


INTENDED USE

This VEGF ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures.The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of VEGF in the sample, this VEGF ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus VEGF concentration. The concentration of VEGF in the samples is then determined by comparing the O.D. of the samples to the standard curve.


PRINCIPLE OF THE ASSAY


The kit assay VEGF level in the sample,use Purified antibody to coat microtiter


plate wells, make solid-phase antibody, Samples which including standards of known concentrations and unknowns are pipetted into coated microtiter wells, after Incubating ,add Biotinylated anti-IgG,and Combined Streptavidin-HRP, become antibody – antigen - enzyme- antibody complex, after washing Compley, Add TMB substrate solution, TMB Chromogen Solution Becomes blue color At HRP enzyme-catalyzed, And at the effect of acid the color finally become yellow, The intensity of this coloured product is directly proportional to the concentration of VEGF present in the samples. measure the optical densit (OD) at 450 nm with microtiter plate reader, calculate VEGF concentration by standard curve.


REAGENTS PROVIDED


All reagents provided are stored at 2-8° C. Refer to the expiration date on the label.

  1. MICROTITER PLATE 48 wells
  2. Biotinylated anti-IgG 3.0 mL 1 tube

3. STANDARD(800 pg/ml)

0.5ml 1 tube

4. STREPTAVIDIN-HRP

3.0 mL

1 tube

5. STANDARD DILUENT

1.5ml

1 tube

  1. Chromogen Solution A 3.0 mL 1 vial
  2. Chromogen Solution B 3.0 mL 1 vial
  3. STOP SOLUTION 3.0 mL 1 vial


  1. WASH SOLUTION x20 20 mL 1 vial
  2. Instruction 1


SAMPLE COLLECTION AND STORAGE

Serum- Use a serum separator tube(SST) and allow samples to clot for 30minutes before centrifugation for 15minutes at approximay 1000 x g.Remove serum and assay immediay or aliquot and store samples at -20 °C or -80°C.


Plasma - Collect plasma using EDTA or heparin as an anticoagulant.Centrifuge samples for 15 minutes at 1000 x g at 2-8°C within 30minutes of collection.Store samples at -20°C or -80°C.Avoid repeated freeze-thaw cycles.


Cell culture fluid and other biological fluids - Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20°C or -80°C.Avoid repeated freeze-thaw cycles.


NOTE: Serum, plasma, and cell culture fluid samples to be used within 7 days may be stored at 2-8°C, otherwise samples must stored at -20°C(≤2months) or -80°C(≤6months) to avoid loss of bioactivity and contamination. Avoid freeze-thaw cycles .When performing the assay slowly bring samples to room temperature.


DO NOT USE HEAT-TREATED SPECIMENS.


MATERIALS REQUIRED BUT NOT SUPPLIED


  1. Microplate reader capable of measuring absorbance at 450 nm.


  1. Precision pipettes to deliver 2 ml to 1 ml volumes. .
  2. Adjustable 10ml -100ml pipettes for reagent preparation.
  3. 100 ml and 1 liter graduated cylinders.
  4. Calibrated adjustable precision pipettes, preferably with disposable plastic tips. (A manifold multi-channel pipette is desirable for large assays.)
  5. Absorbent paper.


  1. 37°C incubator.
  2. Distilled or deionized water.
  3. Data analysis and graphing software..
  4. Tubes to prepare standard or sample dilutions.


PRECAUTIONS


  1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.


  1. Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.


  1. Do not use kit components beyond their expiration date.


  1. Use only deionized or distilled water to dilute reagents.

5.   Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.

  1. Use fresh disposable pipette tips for each transfer to avoid contamination.


  1. Do not mix acid and sodium hypochlorite solutions.

8.  Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from human blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.

  1. All samples should be disposed of in a manner that will inactivate viruses.


  1. Solid Waste: Autoclave 60 min. at 121°C.

11.  Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.


  1. Substrate Solution is easily contaminated. If bluish prior to use, do not use.


  1. Chromogen Solution B contains 20% acetone, keep this reagent away from sources of heat or flame.


  1. Remove all kit reagents from refrigerator and allow them to reach room


temperature ( 20-25°C).


REAGENT PREPARATION


Standard -The Kit provides a stock standard800 pg/ml. Allow the standard to sit for a minimum of 5 minutes with gentle mixing prior to making dilutions.Pipette 150μL of Standard Dilution into each tube.


(total 5 tubes) Use the 150μL of stock solution to produce a 2-fold dilution series (including 400 pg/ml,200 pg/ml,100 pg/ml,50 pg/ml , 25 pg/ml). Mix each tube thoroughly before the next transfer.


Wash Buffer - If crystals have formed in the concentrate, warm to room temperature and mix gently until the crystals have compley dissolved. To prepare enough Wash Buffer for one plate, add 20mL Wash Buffer Concentrate into deionized or distilled water to prepare 600mL of Wash Buffer.


ASSAY PROCEDURE


Prepare all Standards before starting assay procedure (see Preparation Reagents). It is recommended that all Standards and Samples be added in duplicate to the Microtiter Plate.


1.       Determine the number of microwell strips required to test the desired number of samples, Each sample, standard and blank should be assayed in duplicate.


  1. add sample: Set blank wells separay (blank comparison wells dont add


sample and ELISA reagent, other each step operation is same). Add 50 μL of Standards or Samples to the appropriate well of the antibody pre-coated Microtiter Plate, and Gently mix. Incubate for 45 min at 37


  1. Configurate liquid: 30 times of wash solution diluted 30 times with distilled water and reserve.
  2. washing: remove Liquid, dry by swing, add washing buffer to every well, still for 30 second then remove, repeat 4 times.


  1. add Biotinylated anti-IgG: Add diluted Biotinylated anti-IgG 50ul to all


wells, Incubate for 30 min at 37


  1. washing:  Operation with 4.


  1. add streptavidin-HRP:  Add streptavidin-HRP 50ul to all wells, Gently mix


Incubate for 15 min at 37


  1. washingOperation with 4.


  1. color: Add Chromogen Solution A 50ul and Chromogen Solution B to each well,Incubate for 15 min at 37


  1. Stop the reaction: Add Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color Immediay).


  1. assay: take blank well as zero , measure the optical densit (OD) at 450 nm after Adding Stop Solution and within 15min.


CALCULATION OF RESULTS

Average the duplicate readings for each standard,control, and sample and subtract the average zero standard optical density. Construct a standard curve by plotting the mean absorbance for each standard on the y-axis against the concentration on the x-axis and draw a best fit curve through the points on the graph. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7
上海慧穎生物科技有限公司 版權(quán)所有    備案號:滬ICP備12016933號-2

技術(shù)支持:化工儀器網(wǎng)    管理登陸    網(wǎng)站地圖

聯(lián)系電話:
15821734033

微信服務(wù)號

教官趁她睡着吸允她的花蜜| 精品熟人妻一区二区三区四区不卡| 国产精品美女久久久免费| 国产精品偷窥熟女精品视频| 乳妓h军妓调教hh文| 成人亚洲a片v一区二区三区蜜月| 亚洲AV中文无码字幕色三| 高h全肉np放荡日记| 人人妻人人澡人人爽欧美一区| 久久夜色精品国产欧美乱| 拨开丁字裤揉捏H| 久久久96人妻无码精品蜜桃| 中文乱码人妻系列一区二区| 国产肉体xxxx裸体784大胆| 99e久热只有精品8在线直播| 欧美精品V国产精品V日韩精品| 黎明破晓前电视剧全集免费观看 | 996久久国产精品线观看| 麻豆人妻少妇精品无码区| 777久久人妻少妇嫩草av| 男人亚洲成色av网站| 少妇与公做了一夜伦理| 欧美熟妇dodk巨大| 免费国产黄网站在线观看可以下载| 久久久久久精品成人免费图片| 八戒八戒在线观看免费完整版| 午夜精品一区二区三区免费视频| 国产精品一区| 亚洲AV无码一区二区三区网址| 性妇bbw搡bbbb搡bbbb| 波多野结衣456| 东北妇女精品BBWBBW| 大学生特殊的按摩精油| 天堂AV无码AV一区二区三区| 久久国产精品99久久久久久| 国产精品久久久久久AV| 小秘书夹得真紧好爽h调视频| 免费漫画网站| 精品人妻少妇一区二区三区在线 | 国产精品视频一区二区噜噜| 医生h调教纯情丫头扩y器|